{"product_id":"a-menarini-diagnostics-glucometro-glucomen-areo-2k-per-automisurazione-della-glicemia-da-sangue-intero-capillare-dimensione-855x56x182-mm-peso-46-g-glucomen","title":"Glucomen Areo 2k Glucometer for Self-Monitoring of Capillary Whole Blood Glucose Size 85.5x56x18.2 mm Weight 46 g Glucomen","description":"\u003ch2 style=\"font-size: medium;\"\u003e GLUCOMEN AREO 2K GLUCOMETER FOR SELF-MEASUREMENT OF BLOOD SUGAR FROM CAPILLARY WHOLE BLOOD DIMENSIONS 85.5X56X18.2 MM WEIGHT 46 G GLUCOMEN\u003c\/h2\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e GLUCOMEN AREO\u003c\/h3\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e GlucoMen\u003cbr\u003e 2K plane\u003c\/h3\u003e\n\u003cdiv align=\"justify\"\u003e\n\n \u003cb\u003eDescription\u003c\/b\u003e \u003cbr\u003e\u003ci\u003eIn vitro\u003c\/i\u003e diagnostic medical device.\u003cbr\u003e System for self-monitoring of blood glucose and ketonemia.\u003cbr\u003e System indicated for the quantitative determination of glucose and beta-hydroxybutyrate (beta-ketone) concentration in fresh capillary whole blood.\u003cbr\u003e Designed for self-monitoring of diabetes mellitus, for monitoring and controlling blood glucose and ketonemia, it can also be used in hospital settings by medical personnel.\u003cbr\u003e It is not intended for the diagnosis or screening of diabetes and ketonemia, nor for use on neonates.\u003cbr\u003e Do not change your therapy based on the results of tests performed with the instrument without first consulting your doctor or healthcare professional.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGeneral characteristics\u003c\/b\u003e\u003cbr\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"1\" width=\"550\"\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eTest strip\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e exclusively GlucoMen areo Sensor and GlucoMen areo Beta-Ketone Sensor\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eBlood sugar measurement\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e specificity for beta-D-glucose in blood\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n \u003ctd\u003e\u003cb\u003eEnzyme composition (per \u003csup\u003ecm2\u003c\/sup\u003e ) of a test strip for measuring blood glucose\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e - glucose oxidase (from \u003ci\u003eAspergillus niger\u003c\/i\u003e ), 3.5%\u003cbr\u003e - mediator: hexacyanoferrate (III) ion, 17.5%\u003cbr\u003e - non-reactive substances, 79%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eMeasurement of blood ketonemia\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e beta-hydroxybutyrate (beta-ketone) in the blood\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eEnzyme composition (per \u003csup\u003ecm2\u003c\/sup\u003e of a test strip for measuring ketonemia)\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e - D-3-hydroxybutyrate dehydrogenase ( \u003ci\u003ePseudomonas sp.\u003c\/i\u003e ) 1.5% w\/w\u003cbr\u003e - coenzyme (NAD+), 0.7% w\/w\u003cbr\u003e - redox mediator: 1,10-phenanthroline-5,6-dione, 20.0% w\/w\u003cbr\u003e - non-reactive substances: 77.8% w\/w\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e \u003cb\u003eUnit of measurement\u003c\/b\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Glucose\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e mg\/dL (not modifiable)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Beta-ketone\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e mmol\/L (not modifiable)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e \u003cb\u003eMeasuring range\u003c\/b\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Glucose\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e 20-600 mg\/dL\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Beta-ketone\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e 0.1-8.0 mmol\/L\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e \u003cb\u003eResponse time\u003c\/b\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Glucose\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e 5 seconds\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Beta-ketone\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e 8 seconds\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e \u003cb\u003eSample volume\u003c\/b\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Glucose\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e 0.5 microL\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Beta-ketone\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e 0.8 microL\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e \u003cb\u003eAcceptable Hematocrit Range\u003c\/b\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Glucose\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e 10-70% (compensated hematocrit)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n \u003ctd\u003eBeta-ketone\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e 20-60% (compensated hematocrit)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eGlucose Test Calibration\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e The results are equivalent to the glucose concentration in plasma (capillary plasma). The GlucoMen areo 2K system is calibrated to capillary plasma values ​​determined with a Yellow Springs 2300 analyzer (YSI). The YSI analyzer is calibrated (as a secondary reference measurement procedure) using a set of YSI standards (primary calibrators) acquired directly from NIST (National Institute of Standards and Technology, USA).\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eKetone test calibration\u003c\/b\u003e\n\u003c\/td\u003e\n\n \u003ctd align=\"Center\"\u003eThe GlucoMen areo 2K system has been calibrated to plasma reference values ​​determined with a Stanbio Beta-Hydroxybutyrate LiquiColor procedure, Procedure No. 2440 (Stanbio Laboratory, 1261 North Main Street, Boerne, Texas 78006). The analyzer using the Stanbio kit (secondary reference measurement procedure) has been calibrated with a series of beta-hydroxybutyrate-containing standards (primary calibrators) prepared gravimetrically at Stanbio Laboratory.\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eHygiene\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e Automatic ejection of the test strip via dedicated ejection button\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eSampling\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e automatic blood sample aspiration by capillary action\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eBVC\u003c\/b\u003e\n\u003c\/td\u003e\n\n \u003ctd align=\"Center\"\u003econtrol of aspirated blood volume. The blood is self-aspirated by capillary action from the sensor and as soon as it reaches the detection electrode, the measurement starts automatically. The reaction does not occur if the blood volume of the sample does not reach the minimum required quantity (if the volume is insufficient, the error Er 3 is displayed)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eUse of alternative sites (AST)\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e allowed (palm and forearm)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eMemory capacity\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e 730 glucose results and 100 Beta-ketone results with markers, dates and times. When the memory is full, the new result will replace the oldest one\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eExternal connection\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e via dedicated cable, NFC or Bluetooth device\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eOutput Specifications\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e USB connection cable available free of charge by calling the A. Menarini Diagnostics Customer Service toll-free number 800 869110\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eBattery life\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e 900 tests minimum, or approximately 1 year (2-3 tests per day)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e \u003cb\u003eOperating environment\u003c\/b\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Glucose\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e temperature: 5-45°C \u003cbr\u003eRelative humidity: 20%-90% (non-condensing)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Beta-ketone\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e temperature: 10-40°C\u003cbr\u003e relative humidity: \u0026lt;85%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eDimensions\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 85.5mm (W) x 56mm (D) x 18.2mm (H)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cb\u003eWeight\u003c\/b\u003e\n\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e 46 g (without batteries)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e \u003cu\u003eBlood glucose test procedure\u003c\/u\u003e\u003cbr\u003e 1. Insert a new GlucoMen areo Sensor (white) into the sensor port. The drop symbol will start flashing on the display and the glucose symbol \"Glu\" will appear in the bottom left corner. If nothing appears on the display, remove the sensor, reinsert it into the port and wait for the drop symbol to start flashing.\u003cbr\u003e For information on how to use the lancing device, read the instructions for use provided with it.\u003cbr\u003e 2. Hold the tip of the sensor in contact with the drop of blood until the control window fills. You will then hear a beep (if enabled) and the display will show a countdown. \u003cbr\u003e3. Read the test results. A beep will announce the appearance of the test result on the screen with the glucose symbol \"Glu\".\u003cbr\u003e 4. To remove the sensor, press the eject button. The instrument will turn off.\u003cbr\u003e\u003cbr\u003e \u003cu\u003eKetonemia test procedure\u003c\/u\u003e\u003cbr\u003e 1. Insert a new GlucoMen areo Beta-Ketone Sensor (light purple) into the sensor port. The drop symbol will start flashing on the display and the ketone symbol \"Keth\" will appear in the bottom left. If nothing appears on the display, remove the sensor, reinsert it into the port and wait for the drop symbol to start flashing.\u003cbr\u003e 2. Hold the tip of the sensor in contact with the drop of blood until the control window fills. You will hear a beep (if enabled) and the display will show a countdown. \u003cbr\u003e3. Read the test results. A beep will announce the appearance of the test result on the screen with the ketone symbol \" Keth\". The symbol will flash until the meter turns off.\u003cbr\u003e 4. To remove the sensor, press the eject button. The instrument will turn off.\u003cbr\u003e Do not use the GlucoMen areo Beta-Ketone Sensor to test samples from alternative sites: use only fresh capillary blood from the fingertip.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e Keep the instrument, sensors and other components out of the reach and sight of children. Small parts may pose a choking hazard.\u003cbr\u003e Handle the bottle and sensors with clean, dry hands.\u003cbr\u003e Dispose of the used bottle and sensors according to local regulations.\u003cbr\u003e Handling blood can be dangerous: use extreme caution when handling blood, sensors, lancets, and the meter.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e\u003cbr\u003e Storage conditions of the instrument: \u003cbr\u003e- temperature: -20-50°C;\u003cbr\u003e - relative humidity: 20-90%.\u003cbr\u003e Do not store or use the instrument in environments where:\u003cbr\u003e - the temperature may fluctuate rapidly;\u003cbr\u003e - humidity is high and causes condensation (bathroom, laundry room, kitchen, etc.);\u003cbr\u003e - there is a strong electromagnetic field (near a microwave oven, a cell phone, etc.).\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e Pack of 1 piece.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCode\u003c\/b\u003e 49195\u003c\/div\u003e","brand":"Glucomen","offers":[{"title":"Default Title","offer_id":50603175739684,"sku":"939605061","price":51.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/8934\/5572\/files\/immagine-1-a-menarini-diagnostics-glucometro-glucomen-areo-2k-per-automisurazione-della-glicemia-da-sangue-intero-capillare-dimensione-855x56x182-mm-peso-46-g-glucomen.jpg?v=1746033047","url":"https:\/\/bfarmi.com\/en\/products\/a-menarini-diagnostics-glucometro-glucomen-areo-2k-per-automisurazione-della-glicemia-da-sangue-intero-capillare-dimensione-855x56x182-mm-peso-46-g-glucomen","provider":"bfarmi.com","version":"1.0","type":"link"}