{"title":"MUNUS INTERNATIONAL","description":null,"products":[{"product_id":"munus-international-test-celiachia-autodiagnostico-munus-medical-determinazione-anticorpi-anti-dgpigaigg-nel-sangue-ean-8056364168506","title":"Munus Medical Celiac Disease Self-Test Anti-dgp\/iga\/igg Antibody Determination In Blood","description":"\u003ch2 style=\"font-size: medium;\"\u003e MUNUS MEDICAL SELF-DIAGNOSTIC CELIAC TEST DETERMINATION OF ANTI-DGP\/IGA\/IGG ANTIBODIES IN THE BLOOD\u003c\/h2\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e\u003c\/h3\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e MUNUS MEDICAL\u003c\/h3\u003e\n\u003cdiv align=\"justify\"\u003e\n\n\u003ch3 style=\"font-size: medium;\"\u003e TEST\u003cbr\u003e CELIAC DISEASE\u003c\/h3\u003e\n\u003ch3 style=\"font-size: medium;\"\u003e SELF-DIAGNOSTIC\u003c\/h3\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Self-test for the determination of anti-deamidated gliadin (anti-DGP) antibodies, IgA and IgG, in the blood for celiac disease screening.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e 1) Wash your hands with warm water and soap, rinse with clean water and dry or use the cleansing gauze provided. Note: the use of warm water facilitates the collection of capillary blood because it induces vasodilation.  \u003cbr\u003e2) Prepare the necessary material as follows: open the aluminum bag, take only the cassette and throw away the desiccant sachet. Open the plastic bag containing the pipette. Open the vial by unscrewing the white cap, being careful not to drop it.\u003cbr\u003e 3) Carefully rotate the protective cap of the lancet 360° without pulling it. Remove and discard the released cap.\u003cbr\u003e 4) Carefully massage the phalanx chosen for the puncture (the side of the ring finger is recommended). It is important to massage from the palm of the hand to the phalanx, to improve blood flow. Press the lancet, from the side from which the cap was removed, against the fingertip. The tip of the lancet automatically retracts safely after use. If the lancet does not work properly, use the second one provided. If the latter is not necessary, it can be disposed of without special precautions. \u003cbr\u003e5) Keeping your hand facing down, massage your finger until a large drop of blood forms. It is important to massage from the palm of your hand to the knuckle, to improve blood flow.\u003cbr\u003e 6) Take the pipette without pressing the bulb. Two sampling methods are suggested:\u003cbr\u003e - hold the pipette horizontally without pressing the bulb and put it in contact with the drop of blood, it will enter by capillarity. Move the pipette away when you reach the black line. If the blood is not enough, continue to massage your finger until you reach that line; \u003cbr\u003e– place the pipette on a flat, clean surface, making sure the tip sticks out, then put the drop of blood in contact with the pipette, it will enter by itself by capillary action. Move your finger away when you reach the black line. If there is not enough blood, continue massaging your finger until you reach that line. Avoid, as much as possible, interrupting the contact between the blood and the pipette to prevent the formation of air bubbles.\u003cbr\u003e 7) Take the previously opened vial and immediately deposit the blood collected with the pipette inside. Press the bulb of the pipette 2 or 3 times and make sure that all the blood has fallen into the diluent solution. Then replace the screw cap on the vial and mix well for at least 10 seconds.\u003cbr\u003e 8) Unscrew the blue cap from the dropper bottle (leave the white cap tightly screwed on). Place 3 drops in the well indicated on the cassette (S). \u003cbr\u003e9) Wait 10 minutes and interpret the results as follows.\u003cbr\u003e INTERPRETATION OF RESULTS\u003cbr\u003e READ THE RESULT AFTER EXACTLY 10 MINUTES\u003cbr\u003e The intensity of the color of the lines has no importance for the interpretation of the test result.\u003cbr\u003e NEGATIVE RESULT\u003cbr\u003e Only one colored line appears under the C (Control) mark. This result indicates that there are no anti-DGP antibodies in the blood or that their level is below the limit detectable by the test.\u003cbr\u003e POSITIVE RESULT\u003cbr\u003e Two colored lines appear in the reading window corresponding to the T (Test) and C (Control) marks. The intensity of the T line may be lower than the C line. The test must therefore be considered positive regardless of the intensity of the T test band. This result indicates the presence of anti-DGP antibodies in the blood and therefore a probable Celiac disease. It is necessary to consult your doctor to continue the diagnostic process.\u003cbr\u003e INVALID RESULT  \u003cbr\u003eNo lines appear or only one line appears under the T (Test) sign and not under the C (Control) sign. In this case it is not possible to interpret the Test result which must be considered invalid, it is recommended to perform a new test.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e 1. Read these instructions for use carefully before performing the Test. The Test is reliable if the instructions are carefully followed.\u003cbr\u003e 2. Keep the Test out of the reach of children.\u003cbr\u003e 3. Do not use the Test after the expiration date or if the package is damaged.\u003cbr\u003e 4. Follow the procedure exactly, respecting the indicated quantities of blood and diluent.\u003cbr\u003e 5. Do not freeze.\u003cbr\u003e 6. Use the Test and the lancet only once.\u003cbr\u003e 7. The Test is for external use only. DO NOT INGEST.\u003cbr\u003e 8. In vitro diagnostic device for individual use.\u003cbr\u003e 9. Not recommended for use by people taking medicines that thin the blood (anticoagulants) or people who have haemophilia problems. \u003cbr\u003e10. After use, dispose of all components in accordance with local regulations, ask your pharmacist for advice.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e\u003cbr\u003e Store the test components at temperatures between +4°C and +30°C.\u003cbr\u003e Validity with intact packaging: 24 months.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e Package containing:\u003cbr\u003e - hermetically sealed aluminum bag containing: 1 CELIAC TEST cassette and 1 desiccant sachet;\u003cbr\u003e - sterile lancets for self-pricking blood samples;\u003cbr\u003e - dropper bottle containing CELIAC TEST diluent, sufficient for 1 test;\u003cbr\u003e - plastic bag containing 1 pipette for blood sampling;\u003cbr\u003e - alcoholic cleansing gauze;\u003cbr\u003e - 1 instruction sheet for use.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCode\u003c\/b\u003e MM-CEL\u003c\/div\u003e","brand":"Munus International","offers":[{"title":"Default Title","offer_id":50602889707812,"sku":"989872876","price":14.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/8934\/5572\/files\/immagine-1-munus-international-test-celiachia-autodiagnostico-munus-medical-determinazione-anticorpi-anti-dgpigaigg-nel-sangue-ean-8056364168506.jpg?v=1746021893"},{"product_id":"munus-international-test-rapido-autodiagnostico-test-menopausa-munus-medical-rilevazione-qualitativa-ormone-fsh-in-campioni-di-urina-ean-6936983166249","title":"Rapid Self-Diagnostic Test Menopause Test Munus Medical Qualitative Detection of FSH Hormone in Urine Samples","description":"\u003ch2 style=\"font-size: medium;\"\u003e RAPID SELF-DIAGNOSTIC TEST MENOPAUSE TEST MUNUS MEDICAL QUALITATIVE DETECTION OF FSH HORMONE IN URINE SAMPLES\u003c\/h2\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e\u003c\/h3\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e MUNUS MEDICAL\u003c\/h3\u003e\n\u003cdiv align=\"justify\"\u003e\n\n\u003ch3 style=\"font-size: medium;\"\u003e TEST\u003cbr\u003e MENOPAUSE\u003c\/h3\u003e\n\u003ch3 style=\"font-size: medium;\"\u003e SELF-DIAGNOSTIC\u003c\/h3\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Rapid test for the qualitative detection of follicle stimulating hormone (FSH) in a urine specimen. For in vitro self-diagnostic use only.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e \u003cbr\u003eThe urine specimen should be collected in a clean, dry container. A first morning urine specimen is preferable as it generally contains the highest concentration of FSH; however, urine specimens collected at any time of day may be used. Urine specimens that have visible precipitates should be centrifuged, filtered, or allowed to settle to obtain a clear specimen for analysis.\u003cbr\u003e - If you have monthly menstrual cycles, perform the first test during the first week of your cycle (days 2-7, considering day 1 as the first day of your period). If the result is negative but symptoms persist, repeat the second test one week later.\u003cbr\u003e - If you no longer have regular periods, test at any time during the month and repeat with a second test 1 week later. \u003cbr\u003eAllow the urine sample and\/or controls to reach room temperature (15-30°C) before testing.\u003cbr\u003e 1. Determine the day to start testing. (See previous section: \"WHEN TO START TESTING\").\u003cbr\u003e 2. Allow the pouch to reach room temperature before opening. Remove the test from the sealed pouch and use within one hour.\u003cbr\u003e 3. Remove the cap from the test stick, place the absorbent tip in your urine stream or immerse the absorbent tip (=2\/3) in the urine of a clean container for at least 10-15 seconds.\u003cbr\u003e 4. Replace the cap on the test, then place the stick on a clean, stable surface, with the control window facing up, and immediately start the timer.\u003cbr\u003e 5.When the test begins the detection process, you may notice a light colored stream moving across the control window. Read the result after 3 minutes. Do not interpret the result after 10 minutes.\u003cbr\u003e READING THE RESULTS \u003cbr\u003ePOSITIVE: Two lines are visible and the line in the test area (T) is equal to or darker than the line in the control area (C). A positive result means that the FSH level is higher than normal. Record the results and compare them to the graph above for interpretation.\u003cbr\u003e NEGATIVE: Two lines are visible, but the line in the test area (T) is fainter than the line in the control area (C) or no line appears in the test area (T). A negative result means that your FSH level is not currently elevated. Record your results and compare them to the graph above for interpretation. \u003cbr\u003eNULL: The control line does not appear. The most likely reasons for the control line not appearing are insufficient sample volume or incorrect procedural techniques. Review the procedure and retest with a new test. If the problem persists, discontinue use of the test kit immediately and contact your distributor.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e - Do not use after the expiry date.\u003cbr\u003e - The test must remain in the sealed pouch until use.\u003cbr\u003e - Store in a dry place at 2-30°C (36-86°F). DO NOT FREEZE.\u003cbr\u003e - Do not use if case is torn or damaged.\u003cbr\u003e - Keep out of reach of children.\u003cbr\u003e - For in vitro diagnostic use only.\u003cbr\u003e - Do not open the foil test pouch until you are ready to begin testing.\u003cbr\u003e - Use the test only once.\u003cbr\u003e - The used test must be disposed of according to local regulations.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e \u003cbr\u003eStore in the pouch at room temperature or refrigerated (2-30°C). The test is stable until the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use.\u003cbr\u003e Validity with intact packaging: 24 months.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e Kit containing:\u003cbr\u003e - 2 test sticks;\u003cbr\u003e - user manual;\u003cbr\u003e - Biohazard bag for the disposal of biologically hazardous samples.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCod.\u003c\/b\u003e MM-FFS-103H\u003c\/div\u003e","brand":"Munus International","offers":[{"title":"Default Title","offer_id":50603403018532,"sku":"989873106","price":9.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/8934\/5572\/files\/immagine-1-munus-international-test-rapido-autodiagnostico-test-menopausa-munus-medical-rilevazione-qualitativa-ormone-fsh-in-campioni-di-urina-ean-6936983166249.jpg?v=1746039817"},{"product_id":"munus-international-test-rapido-autodiagnostico-test-covid-munus-medical-rilevazione-qualitativa-antigeni-sars-cov-2-in-campioni-nasali-ean-6936983167703","title":"Rapid Self-Diagnostic Test Covid Test Munus Medical Qualitative Detection of Sars-CoV-2 Antigens in Nasal Samples","description":"\u003ch2 style=\"font-size: medium;\"\u003e RAPID SELF-DIAGNOSTIC TEST COVID MUNUS MEDICAL QUALITATIVE DETECTION OF SARS-COV-2 ANTIGENS IN NASAL SAMPLES\u003c\/h2\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e\u003c\/h3\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e MUNUS MEDICAL\u003c\/h3\u003e\n\u003cdiv align=\"justify\"\u003e\n\n\u003ch3 style=\"font-size: medium;\"\u003e COVID TESTING\u003c\/h3\u003e\n\u003ch3 style=\"font-size: medium;\"\u003e SELF-DIAGNOSTIC\u003c\/h3\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Rapid test for the qualitative detection of SARS-CoV-2 Nucleocapsid Protein antigens in nasal swab specimens. For in vitro self-diagnostic use only.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e Wash your hands with soap and water for at least 20 seconds before and after testing. If soap and water are not available, use a hand sanitizer with at least 60% alcohol. Remove the cap from the extraction swab tube and place the tube in the tube holder in the box.\u003cbr\u003e Nasal swab sample collection\u003cbr\u003e 1. Remove the sterile swab from the pouch. \u003cbr\u003e2. Insert the swab into the nostril until you feel a slight resistance (about 2 cm up the nose). Slowly rotate the swab, rubbing it along the inside of the nostril 5-10 times against the nasal wall.\u003cbr\u003e Note: This may be uncomfortable. Do not insert the swab further if you feel strong resistance or pain. When the nasal mucosa is damaged or bleeding, collecting a nasal swab is not recommended. If you are collecting swabs from others, please wear a face mask. With children, it may not be necessary to insert the swab so far into the nostril. For very young children, another person may be needed to hold the child's head while collecting the swab.\u003cbr\u003e 3. Gently remove the swab.\u003cbr\u003e 4. Using the same swab, repeat step 2 in the other nostril.\u003cbr\u003e 5. Remove the swab.\u003cbr\u003e Sample preparation \u003cbr\u003e1. Place the swab in the extraction tube, make sure it touches the bottom and shake the swab to mix well. Press the head of the swab against the tube and rotate the swab for 10-15 seconds.\u003cbr\u003e 2. Remove the swab by pressing the swab head against the inside of the extraction tube. Place the swab in the biosafety bag.\u003cbr\u003e 3. Close the cap or insert the tip of the tube onto the tube.\u003cbr\u003e Test\u003cbr\u003e 1. Remove the test cassette from the sealed foil pouch and use it within one hour. Best results are obtained if the test is performed immediately after opening the foil pouch. Place the test cassette on a flat surface.\u003cbr\u003e 2. Invert the sample extraction tube and add 3 drops of the extracted sample to the well (S) of the test cassette and start the timer. Do not move the test cassette during test development.\u003cbr\u003e 3. Read the result at 15 minutes. Do not read the result after 20 minutes. \u003cbr\u003eNote: At the end of the test, place all components in the plastic biosafety bag and dispose of according to local regulations.\u003cbr\u003e POSITIVE: *Two colored lines appear. One colored line should appear in the control region (C) and another colored line should appear in the test region (T).\u003cbr\u003e *NOTE: The intensity of the color in the test line region (T) varies depending on the number of SARS-CoV-2 antigens present in the sample. Therefore, the presence of any shade of color in the test region (T) should be interpreted as a POSITIVE result. A positive result means that the person is very likely to be infected with COVID-19, positive samples should be confirmed. Immediately self-isolate as per local regulations and contact your doctor or district health care provider as instructed by local authorities. \u003cbr\u003eNote: Do not make any medical decisions without first consulting your doctor.\u003cbr\u003e NEGATIVE: Only one colored line appears in the control region (C). No colored lines appear in the test line region (T). It is unlikely that you have COVID-19. However, this test may give an incorrect result (a false negative) in some people with COVID-19. This means that you may have COVID-19 even if the test gave a negative result. You can also repeat the test with a new kit. If you suspect that you have COVID-19, repeat the test after 1-2 days as coronavirus cannot be detected at all stages of infection.\u003cbr\u003e Even with a negative result, distancing and hygiene rules must continue to be observed. Migration\/travel, attendance at events, etc. should follow local COVID guidelines\/requirements.\u003cbr\u003e INVALID: The control line does not appear. \u003cbr\u003eInsufficient sample volume or improper procedure techniques are the most likely causes of missing control line. Review the procedure and repeat the test with a new kit or contact your healthcare provider or a COVID-19 testing center.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e - For self-testing for in vitro self-diagnostic use only. Do not use after the expiration date.\u003cbr\u003e - Do not eat, drink or smoke in the area where specimens or kits are handled.\u003cbr\u003e - Do not drink the swab liquid contained in the kit. Handle the swab with care and avoid contact with skin or eyes, rinse immediately with plenty of running water in case of contact.\u003cbr\u003e - Please do not use if the foil package is damaged or has been opened.\u003cbr\u003e - This test kit should be used only as a preliminary test and repeatedly abnormal results should be discussed with a doctor or medical professional.\u003cbr\u003e - Strictly follow the indicated time.  \u003cbr\u003e- Use the test only once. Do not disassemble and touch the test window of the test cassette.\u003cbr\u003e - The kit must not be frozen or used after the expiry date printed on the package.\u003cbr\u003e - The test for children should be done under the guidance of an adult.\u003cbr\u003e - Wash hands thoroughly before and after handling.\u003cbr\u003e - Please ensure that adequate amount of sample is used for testing. Too much or too little sample may lead to deviation of results.\u003cbr\u003e 1. Performance was evaluated with nasal swab specimens only, using the procedures provided in this package insert.\u003cbr\u003e 2. The COVID Test for SARS-CoV-2 will only indicate the presence of SARS-CoV-2 antigens in the sample. \u003cbr\u003e3. If the test result is negative or non-reactive and clinical symptoms persist, it is because the virus of very early infection may not be detected; it is recommended to retest with a new kit or test with a molecular diagnostic device to exclude infection in these individuals.\u003cbr\u003e 4. Negative results do not exclude SARS-CoV-2 infection, especially in those who have been in contact with the virus. Follow-up testing with molecular diagnostics should be considered to exclude infection in these individuals.\u003cbr\u003e 5. Positive COVID-19 results may be due to infection with non-SARS-CoV-2 coronavirus strains or other interfering factors.\u003cbr\u003e 6. Failure to follow these procedures may impair test performance.\u003cbr\u003e 7. False negative results may occur if a specimen is improperly collected or handled. \u003cbr\u003e8. False negative results may occur if there are insufficient levels of virus in the sample.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e\u003cbr\u003e Store as packaged in the sealed pouch at room temperature or refrigerated (2-30° C). The test is stable until the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.\u003cbr\u003e Validity with intact packaging: 24 months.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e Kit containing:\u003cbr\u003e - test box;\u003cbr\u003e - user manual;\u003cbr\u003e - extraction swab;\u003cbr\u003e - sterile swab;\u003cbr\u003e - biosecurity bag.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCod.\u003c\/b\u003e MM-INCP-502H\u003c\/div\u003e","brand":"Munus International","offers":[{"title":"Default Title","offer_id":50604260000036,"sku":"989872890","price":7.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/8934\/5572\/files\/immagine-1-munus-international-test-rapido-autodiagnostico-test-covid-munus-medical-rilevazione-qualitativa-antigeni-sars-cov-2-in-campioni-nasali-ean-6936983167703.jpg?v=1746081349"},{"product_id":"munus-international-test-streptococco-a-autodiagnostico-munus-medical-rilevazione-batterio-streptococco-b-emolitico-di-gruppo-a-da-tampone-faringeo-ean-8056364168513","title":"Munus Medical Self-Diagnostic Strep A Test for the Detection of Group A Beta-Hemolytic Streptococcus from a Pharyngeal Swab","description":"\u003ch2 style=\"font-size: medium;\"\u003e MUNUS MEDICAL SELF-DIAGNOSTIC STREPTOCOCCUS TEST DETECTION OF GROUP A B-HEMOLYTIC STREPTOCOCCUS BACTERIA FROM THROAT SWAB\u003c\/h2\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e\u003c\/h3\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e MUNUS MEDICAL\u003c\/h3\u003e\n\u003cdiv align=\"justify\"\u003e\n\n\u003ch3 style=\"font-size: medium;\"\u003e TEST \u003cbr\u003eSTREPTOCOCCUS A\u003c\/h3\u003e\n\u003ch3 style=\"font-size: medium;\"\u003e SELF-DIAGNOSTIC\u003c\/h3\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Self-test for the detection of group A beta-haemolytic streptococcus bacteria from throat swab.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e 1) Wash your hands with warm water and soap, rinse with clean water and dry.\u003cbr\u003e 2) Place the empty plastic tube into the hole on the back of the package.\u003cbr\u003e 3) Sample collection:\u003cbr\u003e - open the package containing the tongue depressor, keeping it inside without removing it, and place it next to you;\u003cbr\u003e - open the package containing the sterile swab, avoiding touching the cotton tip, and remove it by grasping the plastic handle;\u003cbr\u003e - stand in front of the mirror, tilt your head back and open your mouth as wide as possible;\u003cbr\u003e - with one hand, grasp the tongue depressor and use it to flatten the tongue downwards; \u003cbr\u003e- With your other hand, bring the swab to your throat and touch the back of your throat, around your tonsils, and any red or sore areas (soft palate, uvula) with the cotton tip. It is recommended to rotate the swab to increase the amount of sample collected. If you have difficulty, ask someone to help you with the collection phase.\u003cbr\u003e 4) After collecting the sample, insert the cotton tip of the swab into the plastic tube provided, previously placed in the appropriate hole in the box.\u003cbr\u003e 5) Open the STREPT A TEST - R1 vial by unscrewing only the blue cap (leaving the white part tightly screwed on), then place 4 drops inside the test tube and close the cap.\u003cbr\u003e 6) Next, open the STREPT A _R2 bottle by unscrewing only the green cap (leaving the white part tightly screwed on), then place 4 drops inside the test tube and close the cap. \u003cbr\u003eWARNING: adding R2 to R1 leads to the formation of a solution for which the indications described in points 8 and 9 of the \"precautions\" apply.\u003cbr\u003e 7) Holding the swab by the plastic handle, rotate it thoroughly against the walls of the tube about 10 times to mix the solution. Leave the swab there for an incubation time of 2-5 minutes.\u003cbr\u003e 8) Once the incubation period is over, remove the tube from the hole in the package (with the swab and extraction fluid still inside) and, using your thumb and forefinger, press the walls of the tube to squeeze the cotton tip of the swab to collect as much fluid as possible inside the tube, removing the swab itself. Dispose of the swab in a waste container according to local regulations and replace the tube inside the support hole on the back of the test package.\u003cbr\u003e 9) Add the dropper provided to the plastic test tube. \u003cbr\u003e10) Dispense 1 drop into the cassette well.\u003cbr\u003e Note: If the dispensed drop contains air bubbles, please dispense a second drop into the well.\u003cbr\u003e 11) Read results after 5 minutes (some positive results may be evident after 1 minute). Do not read after 10 minutes.\u003cbr\u003e INTERPRETATION OF RESULTS\u003cbr\u003e READ THE RESULT AFTER 5 MINUTES.\u003cbr\u003e POSITIVE RESULT\u003cbr\u003e Two colored lines appear in the reading window at the T (Test) and C (Control) marks. The intensity of the T line may be lower than the C line. The test should therefore be considered positive regardless of the intensity of the T test line. This result indicates that the test has detected the presence of specific Streptococcus A antigens in the sample. It is recommended to consult a physician.\u003cbr\u003e NEGATIVE RESULT  \u003cbr\u003eOnly one colored line appears under the C (Control) mark. This result indicates that Strep A antigens were not detected in the throat specimen or were not present in sufficient quantities to be detected.\u003cbr\u003e INVALID RESULT\u003cbr\u003e No lines appear or only one line appears under the T (Test) mark and not under the C (Control) mark. In this case it is not possible to interpret the Test result which must be considered invalid, it is recommended to perform a new test with a new sample.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e - Read the instructions for use carefully before performing the test. The test is reliable if the instructions are carefully followed.\u003cbr\u003e - Keep out of reach of children.\u003cbr\u003e - Do not use the test after the expiration date or if the package is damaged.\u003cbr\u003e - Follow the procedure exactly, respecting the indicated quantities of blood and diluent.\u003cbr\u003e - Use the test and the lancet only once.\u003cbr\u003e - The test is for external use only. Do not ingest. \u003cbr\u003e- In vitro diagnostic device for individual use.\u003cbr\u003e - Not recommended for use by people taking medicines that thin the blood (anticoagulants) or people who have haemophilia problems.\u003cbr\u003e - After use, dispose of all components in accordance with local regulations, ask your pharmacist for advice.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e\u003cbr\u003e Store at temperatures between 4°C and 30°C.\u003cbr\u003e Validity with intact packaging: 24 months.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e Package containing:\u003cbr\u003e - 1 test cassette;\u003cbr\u003e - 1 desiccant sachet;\u003cbr\u003e - 1 sterile swab;\u003cbr\u003e - 1 sterile wooden tongue depressor;\u003cbr\u003e - 1 dropper bottle with R2 solution (green cap);\u003cbr\u003e - 1 empty sampling tube with dropper;\u003cbr\u003e - user manual.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCode\u003c\/b\u003e MM-STREP-A\u003c\/div\u003e","brand":"Munus International","offers":[{"title":"Default Title","offer_id":50604260327716,"sku":"989873120","price":14.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/8934\/5572\/files\/immagine-1-munus-international-test-streptococco-a-autodiagnostico-munus-medical-rilevazione-batterio-streptococco-b-emolitico-di-gruppo-a-da-tampone-faringeo-ean-8056364168513.jpg?v=1746081390"},{"product_id":"munus-international-test-prostata-autodiagnostico-munus-medical-rilevazione-antigene-prostatico-specifico-in-campioni-di-sangue-intero-ean-8056364168490","title":"Munus Medical Prostate Self-Test Specific Prostatic Antigen Detection In Whole Blood Samples","description":"\u003ch2 style=\"font-size: medium;\"\u003eMUNUS MEDICAL SELF-DIAGNOSTIC PROSTATE TEST DETECTION OF PROSTATIC SPECIFIC ANTIGEN IN WHOLE BLOOD SAMPLES\u003c\/h2\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e\u003c\/h3\u003e\n\u003cbr\u003e\u003ch3 style=\"font-size: medium;\"\u003e MUNUS MEDICAL\u003c\/h3\u003e\n\u003cdiv align=\"justify\"\u003e\n\n\u003ch3 style=\"font-size: medium;\"\u003e TEST\u003cbr\u003e PROSTATE\u003c\/h3\u003e\n\u003ch3 style=\"font-size: medium;\"\u003e SELF-DIAGNOSTIC\u003c\/h3\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Self-test for the detection of prostate-specific antigen (PSA) in whole blood samples.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e 1) Wash your hands with warm water and soap, rinse with clean water and dry or use the cleansing gauze provided. Note: the use of warm water facilitates the collection of capillary blood because it induces vasodilation.\u003cbr\u003e 2) Prepare the necessary material as follows: open the aluminum bag, take only the cassette and throw away the desiccant sachet. Open the plastic bag containing the pipette. Open the vial by unscrewing the white cap, being careful not to drop it.\u003cbr\u003e 3) Carefully rotate the protective cap of the lancet 360° without pulling it. Remove and discard the released cap. \u003cbr\u003e4) Carefully massage the phalanx chosen for the puncture (the side of the ring finger is recommended). It is important to massage from the palm of the hand to the phalanx, to improve blood flow. Press the lancet, from the side from which the cap was removed, against the fingertip. The tip of the lancet automatically retracts safely after use. If the lancet does not work properly, use the second one provided. If the latter is not necessary, it can be disposed of without special precautions.\u003cbr\u003e 5) Keeping your hand facing down, massage your finger until a large drop of blood forms. It is important to massage from the palm of your hand to the knuckle, to improve blood flow.\u003cbr\u003e 6) Take the pipette without pressing the bulb. Two sampling methods are suggested: \u003cbr\u003e- hold the pipette horizontally without pressing the bulb and put it in contact with the drop of blood, it will enter by capillarity. Move the pipette away when you reach the black line. If the blood is not enough, continue to massage your finger until you reach that line;\u003cbr\u003e – place the pipette on a flat, clean surface, making sure the tip sticks out, then put the drop of blood in contact with the pipette, it will enter by itself by capillary action. Move your finger away when you reach the black line. If there is not enough blood, continue massaging your finger until you reach that line. Avoid, as much as possible, interrupting the contact between the blood and the pipette to prevent the formation of air bubbles. \u003cbr\u003e7) Take the previously opened vial and immediately deposit the blood collected with the pipette inside. Press the bulb of the pipette 2 or 3 times and make sure that all the blood has fallen into the diluent solution. Then replace the screw cap on the vial and mix well for at least 10 seconds.\u003cbr\u003e 8) Unscrew the blue cap from the dropper bottle (leave the white cap tightly screwed on). Place 3 drops in the well indicated on the cassette (S).\u003cbr\u003e 9) Wait 5 minutes and read the results referring to the next section for interpretation of the results.\u003cbr\u003e INTERPRETATION OF RESULTS\u003cbr\u003e READ THE RESULT AFTER EXACTLY 5 MINUTES\u003cbr\u003e The intensity of the color of the lines has no importance for the interpretation of the test result.\u003cbr\u003e POSITIVE RESULT  \u003cbr\u003eTwo colored lines appear in the reading window corresponding to the T (Test) and C (Control) marks. The intensity of the T line may be lower than the C line. The test must therefore be considered positive regardless of the intensity of the T test band. This result indicates the presence of anti-DGP antibodies in the blood and therefore a probable Celiac disease. It is necessary to consult your doctor to continue the diagnostic process.\u003cbr\u003e NEGATIVE RESULT\u003cbr\u003e Only one colored line appears under the C (Control) mark. This result indicates that there are no anti-DGP antibodies in the blood or that their level is below the limit detectable by the test.\u003cbr\u003e INVALID RESULT\u003cbr\u003e No lines appear or only one line appears under the T (Test) sign and not under the C (Control) sign. In this case it is not possible to interpret the Test result which must be considered invalid, it is recommended to perform a new test.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e \u003cbr\u003e- Read the instructions for use carefully before performing the test. The test is reliable if the instructions are carefully followed.\u003cbr\u003e - Keep out of reach of children.\u003cbr\u003e - Do not use the test after the expiration date or if the package is damaged.\u003cbr\u003e - Follow the procedure exactly, respecting the indicated quantities of blood and diluent.\u003cbr\u003e - Use the test and the lancet only once.\u003cbr\u003e - The test is for external use only. Do not ingest.\u003cbr\u003e - In vitro diagnostic device for individual use.\u003cbr\u003e - Not recommended for use by people taking medicines that thin the blood (anticoagulants) or people who have haemophilia problems.\u003cbr\u003e - After use, dispose of all components in accordance with local regulations, ask your pharmacist for advice.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e\u003cbr\u003e Store at temperatures between 4°C and 30°C.\u003cbr\u003e Validity with intact packaging: 24 months.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e Package containing: \u003cbr\u003e- hermetically sealed aluminum pouch containing: 1 cassette of PROSTATE PSA TEST and 1 desiccant sachet;\u003cbr\u003e - sterile lancets for self-pricking blood samples;\u003cbr\u003e - dropper bottle containing the PROSTATE PSA TEST diluent, sufficient for 1 test;\u003cbr\u003e - plastic bag containing 1 pipette for blood sampling;\u003cbr\u003e - alcoholic cleansing gauze;\u003cbr\u003e - 1 instruction sheet for use.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCode\u003c\/b\u003e MM-PSA\u003c\/div\u003e","brand":"Munus International","offers":[{"title":"Default Title","offer_id":50605116129572,"sku":"989873118","price":14.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/8934\/5572\/files\/immagine-1-munus-international-test-prostata-autodiagnostico-munus-medical-rilevazione-antigene-prostatico-specifico-in-campioni-di-sangue-intero-ean-8056364168490.jpg?v=1746111668"}],"url":"https:\/\/bfarmi.com\/en\/collections\/munus-international.oembed","provider":"bfarmi.com","version":"1.0","type":"link"}